here are two more technical questions on MHEG-5. This time, I do not
call directly for a Amendment Process... :-) Last time, it was too fast.
But I am thinking about an extension of the techFAQ from Tom Schwengler
with the recent (and upcoming) issues. Tom, are you still out there??
Q1: Timer: When I run a timer with absolute value (i.e relative to the
scene), and the indicated time has already passed, shall an engine fire
the event off?
my suggestion: yes
this is a clarification only, hence something for the techFAQ
Q2: The action SetData requires the ContentHook of the target to be
encoded. Isn't that too strong?
my suggestion: yes, too strong.
This would be a change in the semantics. Hence, people have to be
aware of this, and this issue might be something to consider during
maintainance of the standard
Any comments?
- Klaus
-- GMD FOKUS German National Research Center for Information Technology Klaus Hofrichter Hardenbergplatz 2 D-10623 Berlin Germany mailto:hofrichter@fokus.gmd.de http://www.fokus.gmd.de/usr/hofrichter Tel +49 30 25499-211 Fax -202 There is a reexamination, but no reparty